Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

sime 80 combi boiler?

Hi,
Hope you can help. We have no hot water but plenty of central heating. Except top radiator not filling.
neil, June 2005
hi neil i suspect the diaphragm in the diverter valve has perished you may have to replece the complete diverter valve if the diaphragm kits are not available. regarding the upstairs radiator try topping up the boiler pressure to 1.5 bar and venting air from the rad hope this helps

joe waldron, June 2005