Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

5 l/min out of 24i worcester combi?

only getting 5 l/min out of boiler,cold water to basin is 15 l/min but hot is 5 l/min
inlet filter clean,could it be the heat exchanger that is scaled???if so how can i clean the heat exchanger
darren, September 2005
there is a small rubber o'ring in the flow restrictor that expands over a period of time and block up the holes in the restrictor-u will need to take the o'ring out it - there is no need to replace it as it serves no purpose

gas man, September 2005
but the boiler still 0nly gives out 5l/min which is POOR

DARREN, September 2005
took the flow restrictor switch off by unscrewing the blue nut and checked the flow restrictor and it moved up and down

darren, September 2005
Check that the flow restrictor. it may be stuck in the flow switch area, I've had this on 2 24i worcesters

Gary the boiler man, September 2005
link Click here to see other fixes for Worcester 24i.