Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

Replacing Pressure Gauge on WB Greenstar 28i?

I've just had a repair and service done on my Woster bosch greenstar 28i and every thing is now working ok. Appart from pressure guage is no longer working. I questioned the engineer just as he was leaving and he made out he hadn't noticed but evey thing was fine and he must of caught and nipped the pipe by accident and he would return and fit a new manometer in the next week. Maybe I shouldn't have paid him the full amount but i suspect he's not going to come back to fix it.
My question is if he doesn't show can I buy a replacement (£20 ebay) and swap it over myself. I'm assuming you have to drain and refill the system. Is this something I could do myself. How would i go about this.
ANON1, September 2010
hi,
you don't need to drain down full heating. look under boiler and there will be 2 slotted valves quarter turn. (make sure they are the heating flow & return) they will be marked the 2 outside ones out of the 5 pipes. then its just a split pin & pull gauge out of housing & replace.
piece of cake!!!

super mario, September 2010