dave s asked ... Transmission not working?    |    Tom asked ... Replace rear right door upper right latch cable - high roof?    |    ian asked ... Vaillant timeswitch 150 analogue unit (clock stopped?    |    Art Cour asked ... How do I get engine cowling off to find gas leaking?    |    liz asked ... Changing a belt?    |    Click here to ask your question

the pressure gauge has gone up to 2.7 on the pressure clock and the boiler?

worcester 24i the pressure gauge has gone up to 2.7 on the pressure gauge and the boiler overflow is constantly dripping and has been doing so for a few days what can i do about it please many thanks mr ,dyer.
mr ,dyer, April 2011
Iagree with Brian, you could do with some who knows what to look for IE gas safe eng.

erj, April 2011
make sure the filling loop is disconnected to start one of the valves could be leaking.

does it over pressurise when its on if yes its possibly a faulty pressure vessel.

I havnt looked but if its a combi boiler it could be a hole in the plate heat exchanger.

Brian Emian Plumbing & Heating, April 2011