Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

Neff U1722 Double Over Earth Tripping?

Purchased a used neff double oven that has not been used.
I turned the bottom oven on then the top oven after about 4 minuites the earth breaker tripped, I reset it turned the bottom oven on all was fine.
Turned the top oven on and it tripped again. I then only turned the top oven on and it tripped another 4 times only on the earth breaker
The earth breaker is rated 63A and the circuit breaker is rated 32 A the circuit breaker is not tripping ?
Graham Bollard, March 2013
The earth circuit breaker is fine i think it could be a problem with the top oven ?
thank you for your replies
Graham

graham, March 2013
An Earth Leakage breaker feeds several circuits each with its own current rating. A typical Earth Leakage Breaker will trip at 30mA leakage but it also has to cope with the combined current of all the circuits it protects - typical 63A or 100A overload breaker.

Peccavi, March 2013
I would like to think the earth breaker is mA not A however this sounds like a classic damp element due to storage.you need to dry the element or replace

CK, March 2013