1 hour ago Ron B asked ... How can I adjust my 2024 Honda Jazz Crossover?    |    vic asked ... How do l get my vauxhall combo radio to work with MP3?    |    Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Click here to ask your question

how to enter pre-set times for Veritas 8 home alarm system?

I have replaced the battery in my Veritas 8 systems, and reset the codes etc. However, there is no pre-set times for exit and entry. How do I pre-set the time for;

a) leaving the property after entering the code to alarm the system
b) entering the property to enter the code to disarm the system
david titterington, August 2007
enter engineer code 1234 (default)
press prog 31 for fullset exit time enter time as two digit number then press prog.repeat for entry time (33)
defaults for both are 30 seconds

paul h, August 2007
link Click here to see other fixes for Veritas 8.