Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Click here to ask your question

Ariston Fault Code - MicroGenus Combi Boiler?

Hi,

My combi keeps cutting out and displaying the code A77. Usually only happens when running HW but could be a co-incidence.

Also - boiler makes a whining noise at times for long periods but only when CH is running - not HW.

Just over a year old but I think they give a 2 year warranty...here's hoping!

Any clues would be helpful!

Thanks.
Richard, November 2007
Need to renew sensor located in the recupirator. The fan has to be removed to do this. Could also be a blocked condensate drain.Both faults will bring up A 77.

m b kenny plumbing, April 2014
My plumber has changed a number of items to no avail, however after taking everything apart he found that the boiler had been installed with a restrictor in the flue. According to Ariston this is a big no no on this type of installation as it causes excessive condensation to be produced which it is not designed to cope with. Another problem can be that the boiler is not straight, this causes water to build up against the sensors and not run away. Restrictor has been removed and to date no more problems. Fingers crossed.

Lee, January 2008
link Click here to see other fixes for Ariston.