Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

hot water flow rate(vokera maxin 24e)?

filling a bath takes forever, cold water flow is at approx.20L/min. With temp setting at mid range flow rate at hot water tap is approx 5-6L/min. I realise that combi's have to heat the water, but this seems really low. It has always been like this . Thanks in advance.
rob, November 2007
after checking the above, try removing the cold feed pipe to the heat exchanger, there you should find another restrictor with an o-ring, remove the o-ring (somtimes swell). this might improve the flow.

Big A, December 2007
First check that the cold water inlet valve is fully open, if so then check if there is an inline filter may be blocked

Ken, November 2007