Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Nick asked ... Oven spark Continuing after lit?    |    Click here to ask your question

How do I fix my Potterton Netaheat MkIIF 16-22?

My boiler starts it's cycle on room stat demand. The internal fan runs, the pilot ignites, after 20 secs the main burner ignites and all is well. The pump appears to work (a)screwdriver to ear and against body of pump b)spindle rotating behind the vent cover) Down stairs rads get slightly warm and then, after about four minutes the main burner shuts down and the pilot remains on. System checked and vented, all seems well. I have replaced the Mercury vapour switch, the pilot ignition system and the 11 pin relay switch with no effect. Having waited eight days for next day delivery, Priceright Heating now tell me the PCB for this boiler is obsolete. Any help would be appreciated
Colin - Hertfordshire, November 2007
even though pump may sound and look ok, does not mean that it is functioning at all. Replace pump

robert McLintock, November 2009
my netaheat boiler the fan came on and off (2-3 second) for 5-6 times before it ignites, what wrong with it?

soon, March 2009
Hi john, I am interested in buying your netaheat 16-22. Could you call me on 07740 454763 if still available.

John F, January 2008
West London John - is your old Netaheat still available? I can't fiind spares for my faulty Mk1 (eg gas valve) and I've got a Corgi mate who'll do the work, if I can find a source of spares. I'm not sure if your gas valve will fit, but it's worth trying! I'm in Bromley so can collect. John

john1000, December 2007
I have just had my Potterton Netaheat MkIIF 16-22 replaced even tho' it was in full working order. A friend was going to give me something for it, but has changed his mind without having seen it. The complete boiler with its flue etc is available and appears to be in good condition , would you be interested. Regular yearly/breakdown servicing by British Gas, whose engineers said system was very clean when changing it over. I am based in West London. Buyer collects only.

John, December 2007
if pilot lite is staying on that means usually with these that the gas valve main solenoid is faulty-either that or the pilot is not stable onto the electrode

wp, December 2007
I am a heating eng and I would not suspect the boiler internal parts. The pcb will either work or not. I expect the pump may be worn out or there is a blockage in the pipes. Try turning off rads downstairs and leave one rad on upstairs to see if it circulates. Then try opening others individually. If it struggles to heat more than one change the pump.

Mo Alexander, December 2007