4 hours ago Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

How do I top up the pressure on my Sime 100e bolier?

Pressure guage has gone to zero and we need to top up, can I DIY ordo I need to call somone?
Ruth J, December 2007
I have one of these boilers. There should be a little valve near the boiler. Mine is blue. Its on a bit of flexible hose. You turn it to the right to let water in then back to 12 o clock to stop the water once the gauge on your boiler is back into the blue (safe). Hope this helps.

B Rodgers, December 2007
turn the handle slowly on filling loop a stainless steel tube fill to the dark blue area only on pressure gauge

Dave c, December 2007
Your boiler has something called a 'filling loop' which effectively allows mains pressure water to be bled into your boiler. You'll have to find this filling loop, and turn it on slowly until you get the correct pressure. Don't overdo it though as you'll have to get the water out again if you do.

John, December 2007