Emma asked ... Foot pedal smoking?    |    Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Click here to ask your question

Vokera Mynute 20SE boiler?

I got some useful feedback to my previous question about large varying pressure in my boiler and the fact that if I charge it up to 1.50bar then overnight it drops to 0.50bar (there being no obvious leaks). Terri suggested re-pressurising the Expansion Vessel in the boiler. When I looked at the bicycle type nipple he described I noticed slight bubbles of water/air coming out and when I pressed the nipple there was a definite flow of water (not air). Does this indicate that the Expansion Vessel/diaphragm is knackered and should be replaced? or is it worthwhile still trying to re-pressurise the Expansion Vessel to 1.0bar?
Frustrated Fifer, December 2007
if theres water coming out the expansion vessel is knackered, you will need ot replacing with either one to go in the same place (if its accessible) or a new remote expansion vessell fitted, you will also need the pressure relief valve replacing because when the boilers overpressurise and dump the water out it generally knackers the press relief!

hope this helps

kev!, December 2007
it shouldnt let water out of the valve

baz, December 2007