GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

I have an Alpha HE CB25/33 boiler?

The heating works fine but there is no hot water. It comes out luke warm when it is on heating and water, but when it's on just water the water is cold.
Can anyone help?
Sheila, January 2008
Hi
Water comes out very hot then droppes to lukewarm realy quickly and stayes that way. No problem with radiators they are running at a constant temperature.
Any ideas?

Paul Wright, March 2015
central heating shuts off after 2 minutes the cums back on after 5 minutes then same again

dave, December 2012
ive just had a diaphram fitted and a flow switch but the boiler is still the same

dav, October 2011
Its the diaphram most likely but you should get someone Gas Safe registered to check it out. There is a good reason why we do all the training and reassessing that we have to do.

Heat Matters, December 2009
i think it mite be the DHW flow switch, really easy to fit your self no screws. go to the alpha web site and down load the installation and servicing manual.

good luck

sheldon, May 2008
its your flow sensor on the hot water side of things

cooldude, May 2008
I'm in the exactly same position with a HE CB25. I'm awaiting a call from a plumber for the solution. This actually started to occur once in a while soon after we had it installed but was told it was related to low water pressure (which it isn't). I'll let you know the out come - if you get any answers my email is danielmcnulty@talktalk.net. Thanks

Daniel McNulty, January 2008