3 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

boiler as gone out and won't relight?

Ferroli Modena 80E combi boiler; pilot has gone out and won't re-light.
Paul Buckland, January 2008
I have to keep reseting my Ferolli modena 80e boiler.
When the boiler tries to ignite for the central heating I have to reset approx 3 times. For hot water I have to turn the tap off, reset a couple of times and then try again.
Any ideas??

Ian Nicholson, May 2008
i want onection my new boiler ferroli modena 80e and i lost instraction. I need help because i dont now with pipe is wather worm and cold

dario, March 2008
There are many reasons that the piolet light wil not relight - check them in order.

Is the system pressured (usually over 1 bar - less will not relight)
Thermocouple failure (replacement use universal termocouple (£6))
Is it powered and fuelled (gas and electric)
System set to 'off' (try hot water+heating, timer set to manual override ON, maximum temperature if adjustable, maximum thermostat) then turn on the electric and wait 30 seconds before trying the igniter.

Steve, February 2008
link Click here to see other fixes for Ferroli.