Sammy asked ... I cannot cancel the delay function on indesit wxl 05?    |    p oneill asked ... How can I mend my SL compact alarm?    |    jaytee asked ... Polti iron continuously steaming?    |    Michelle asked ... How to update firmware?    |    Alan asked ... Waring Blendor DL 202 Armature removal?    |    Click here to ask your question

boilers?

im thinking about changing my back boiler for a conventual wall mounted one, i have a fully pumped system at the mo, now the plumber says,its just a question of hanging the boiler and runnin 2 pipes into the airing cupboard and picking up the flow and return!
could it really be that easy or am i going to be hit with the "oh dear,this wont work, you need a new system"
is this correct?
the tyreman, January 2008
It will work as long as your existing heating outlets from the backboiler are blanked off and all unnecessary 'dead-legs' are removed from the old system which may cause the new system circulation problems. Don't forget the all important chemical flush with 1 litre of Sentinel X800 ferroquest, flush for 3 hours then empty. Then add Sentinel X400 inhibitor

Chemical Ali, January 2008