dave s asked ... Transmission not working?    |    Tom asked ... Replace rear right door upper right latch cable - high roof?    |    ian asked ... Vaillant timeswitch 150 analogue unit (clock stopped?    |    Art Cour asked ... How do I get engine cowling off to find gas leaking?    |    liz asked ... Changing a belt?    |    Click here to ask your question

replace door seal?

how do i remove and replace new door seal to creda simplicity model 17120
John Scattergood, February 2008
Undo the fixing (spring, twisted wire or plastic locking band) which attaches the seal to the outside shell and detach doorseal from outer machine shell. Power off, Remove the machine top, push drum towards the rear of machine and look down to where the doorseal attaches to the drum - you should seen another clamping band. Unscrew this inner drum clamping band and pull the doorseal away. Fitting the new seal is a bit like fitting a bicycle tyre on a new rim but on a bigger scale.Ensure the seal is located correctly and refit both outer and inner clamping devices. Some manufacturers in their wisdom bung the seal beneath a concrete balance weight in the front of the drum.....Jeez. If seal is obstructed by concrete weights the front panel and the concrete weight will have to be removed before seal can be detached.
Check out this site for spares : www.4directelectricals.co.uk
Check out this site for info: www.2ndwave.co.uk/manual.html

dan, February 2008
link Click here to see other fixes for Creda.