Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

vaillant ecotec?

what does f 75 mean
Mr R mitchell, February 2008
Thanks for info,I did know that there was a problem with air or pressure,have not sussed out how to re pressurize system yet,because there is an internal filling loop and having a job getting info.eco pluss 831.

roger desmond weeks, March 2010
Answer 1 works! After day of freezing at home, tried it out! Many thanks!

Anna, January 2010
This answer may upset the techies.
If you have bled off any air and system pressure is correct ie above 0.8 but less than 2, then turn your boiler of at the mains for 1 minute and turn back on. Everything should work. (This is the same as when your desk top PC crashes.)

BSc Hons, IMechE, IEEE, working in IT, April 2008
According to Ecotec manual F75 as follows:
F.75 - No pressure rise was detected on turning on the pump

Water pressure sensor or/and pump defective
Air in the heating system, quick bleeder defective
Too little water in appliance; check adjustable by-pass; connect
external expension vessel to return

Mike Longhurst, February 2008
link Click here to see other fixes for Vaillant.