Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Click here to ask your question

Ferroli 102 DHW intermittent?

My 102 is about 7yrs old. Long been a problem with DHW cycling between hot and cold a nuisance in the shower. Thermistors have been changed, PCB as been changed. Now the boiler will shut down when providing DHW, sometimes requires a reset, sometimes will come OK after time. The whole thing appears to be unpredictable. My service firm have made 7-8 visits in the last month and dont seem to understand the problem.
arbee., February 2008
If the problem only happens with hot water, it is probably the flue fan venturi either cracked or brittle, or the fan impellor is dirty causing insufficient air flow to operate the air pressure switch.

DC, February 2008