1 hour ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

Vaillant Ecotech 837 plus lossing pressure over 3 weeks?

I have noticed when central heating is off boiler pressure drops from 80% to 25% in 2 days. when ch is on takes 3-weeks.
How can I know if there is any leaks as visible pipe work and radiators look ok.
Patel, March 2008
Not 100% sure but if no leaks on system then probably an internal leak in your Domestic Hot Water (secondary) heat exchanger. Allowing central heating pressure to pass into DHW system.
Solution - Replace secondary heat exchanger. Old black "plastic" exchangers are known for this and are obsolete. Replace with new metal exchanger.

Colcreate, April 2008
link Click here to see other fixes for Vaillant Ecotech 837 plus.