Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

how can i fix vokera linea 28 error code 07 [boiler]?

my boiler keeps turning off showing code 07, it will start again when i reset it, but its becoming frequent, the boiler is avokera linea 28
lee poulter, March 2008
How much dose a primary thermistor cost.

Kerry munro, May 2012
you should not attempt to work on any gas appliance unless you are a corgi registered installer ,you could invalidate your house insurance in the event of a fire!

jazzy b, March 2008
07 means the primary thermistor on the heat exchanger is in the open circuit this will have to be replaced

ricky, March 2008