Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Is there a problem with my worcester 35CDi combi boiler?

I have a worcester 35CDi boiler which appears to be OK - however when trying to use a cold water tap whilst the boiler is on producing hot water, after a few seconds the hot water is cold!! Any clues?
Bill Jenkins, March 2008
sounds like a drop in water pressure when you have 2 taps open is affecting the divertor valve which then breaks contact with the hotwater microswitch and the hotwater neon goes out with the boiler following suit. if you think that the flow from the taps is as normal then the divertor valve will be suspect,usually last 5 yrs.worth checking if British gas do a fixed price repair of £156 in your area

combiking, March 2008