Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

worcester heatslave 20/25 cut out keeps comming on?

cut out keeps comming on pump working fine burner is also working presure goes up and down slight leak from red tank can you help
m barnard, March 2008
Fluctuations on the pressure gauge usually mean that the expansion vessel (the red tank) has little or no air pressure inside. This tank is in 2 sections - air on one side (around 10 psi) and water on the other....if there is a leak, it really should be replaced - cost around £80 for the part. The air side has a normal tyre valve fitted for air replenishment - if you depress the valve and water comes out, the diaphragm that separates the 2 halves of the tank has perforated.

John, March 2008