Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Why Intermittent hot water on the Vokera Compact 24?

In DHW/CH mode the heating works fine (all singing all dancing). Turn on the hot water tap and the boiler gas goes out after which there is a process of ignition and hot/warm water flows for a few seconds, then the gas goes out and the process repeats itself. In DHW mode the process is the same. Could anyone inform me is it the secondary Thermistor or the PCB or am i missing the plot?
FreeRange, April 2008
may be a flue problem to check remove the combustion plate if the boiler stays on when the tap is run it is a problem with either the fan, air pressure switch,flue or restrictor

ricky, April 2008