GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

tepid water from worcester bosch 24cdi?

i am only getting tepid hot water from my combi boiler. central heating working fine. i have change the heat exchanger and the diaphram and microswitch. gas valve modulates correctly as per the worcestor helpline. does anyone have any other ideas ?????
sury, April 2008
It could be that your hot water flow is too high to be picking up enough heat in the heat exchanger. With my 24CDi the hot water flowing from a hot water tap is much less than the flow from a cold water tap. There should be a little white disc in line between the diverter valve and the secondary water heat exchanger. This is called the domestic hot water restrictor (or regulator) and limits the hot water flow to about 8 litres per minute. I would check that this is fitted and if so that it is in good order, there is an 'O' ring between the two halves of the assembly that sometimes perishes.

Richard, May 2008
did you check the inline wter filter on the mains water to the boiler?
could be blocked...seen many heatexchagers changed when it was only this!

T, April 2008