3 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

my boiler wont fire up?

wont fire up on heating and hot water 240v present at fan for a second then 0v is this a pcb i need to replace pump running
rik confused plumber, May 2008
sounds sus like a pcb alrite, make sure to check it at the pcb when fan is disconnected (ie. not a problem with fan motor causing the voltage to drop out) would have a better idea if you told us what boiler?

assume the boiler is locking out? you sure all stats & thermisters are ok, flow swtch is making (not comming out, momenterialy then goin back in) as this is a sign of the pump on its way, or the heat exchanger being partially blocked

try give us a fuller picture of the problem, the devil is in the detail