3 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

over pressure baxi 105e?

pressure valve lets go at 3 bar .loop disconected .but water is passing through to heating system and running out of by pass
paul laff, May 2008
Sounds like Diverter valve diaphram valve.
Passing between c/h and h/w supply.?
the 2 mixing. giving presure.
got to be the diverter valve.

Neil.Plumbing, May 2008
Could be domestic heat exchanger. If pinholed inside would pass mains to central heating.

Kevez, May 2008