Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

CENTRAL HEATING TANK IN LOFT OVERFILLING WHY?

I FIITED A NEW BALLCOCK IN TANK BUT THE TANK IS STILL FILLING TO OVERFLOW CAN THE TANK BACK FILL FROM THE SYSTEM ANYHOW? I THOUGHT WATER ONLY CAME IN TO TANK FROM SUPPLY
STEWART, May 2008
could be the cold feed into the house crossing over in the back of a mixer tap and pussing up through the system and into the water tank, you havent stated which tank.

Baz, June 2008
water can backfill on both tanks.

f/e can backfill from a split coil in cylinder.
cws tank can backfill from the cylinder caused by cold mains entering into hot gravity.

what tank is backfilling need more info.

hi-spec plumbing & heating, May 2008
its a feed and expansion tank so yes it will rise when heating on for example. you may have the float set too high so it overflows when expansion occurs