3 hours ago Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

sime 80c format combination boiler?

ch and hw go to lock out after 10 secs of main burner lighting
domestic plumbing services, June 2008
problem with flame rectification probe, if a new installation, check that polarity is correct (ie, live is live and neutral is neutral) as reversed poarity stop flame recification.

if that all checks out, its either the gas valve or the pcb

T, June 2008