Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

ferolli lighting but not staying lit?

as above it lights but will not stay lit, rises to 11.5 mbar as it should then dies off, few seconds. all power to gas valve etc is cut.

ignitor/flame detection seems ok, lead has continuity

exact same problem for dhw/ch is this a pcb fault not recognising flame is present or am i missing something????

gimme a baxi any day
iain, June 2008
cheers T, lead been replaced and still same fault, all earting looks good, boiler only 15mth ish??????

iain, June 2008
lead continuity on flame sensor may not be enough, is it correctly positioned and cleaned? sounds like a flame
rectification problem........possibly pcb related, but would be changing the rectification probe first (and also making sure there was good earthing on the boiler)
try disconeccting the rectification probe and running the boiler, see if the problem is the same one.

T, June 2008