Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Click here to ask your question

gas boiler vaillant vcw 242e, 282e - varying and loss of pressure?

I hope that someome out there could shed some light on this issue.

When using the tap mixer shower the pressure and heats is great, but turn the basin hot tap on and the shower turns to a dribble.

The Second problem is with the Kitchen sink, whilst the pressure from the hot tap is great it takes an age to come out hot, then once we have heat and get a few dishes done! it turns ice cold and the process stars again... as in an age to heat again!

I look forward to reading your replies.

Regards

Ian Nunn
Ian Nunn, August 2005
OK i have the same problem and the answer is that your diaphragm has gone in your hot water pump....This takes a while to happen and gradually gets worse and worse taking a few month to stop working completely but the signs are there with it taking more and more time for the water to heat up until nothing happens at all. You can get around it by manually operating the pump valve (a little black rocker switch on top of the hot water valve). Open this manually using a screwdriver and check your water is heating, if so the diaphragm is damaged and needs replacing.

lee allsopp, October 2006