andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Flushing unvented CH system?

Have a Worcester Heat Slave combi 18 yrs old and am looking to replace with condensing combi.
Would like to flush my system and replace TRV's and Lockshield valve my self to save some money.
Is it his reasonable? I am good at DIY and have most tools.
I realise that this system is unvented, does this make it harder to do? any explanation welcome. Thanks Martin
Martin King, August 2008
Not really.Turn off 1 small rad at both ends and drain.Fill this rad with the inhibitor,turn valves on again ,top up system and run it for however long the inhibitor maker says.Then empty system and remember to fill and empty 2 or 3 times.
Do this before putting the new TRVs on.

Gasman, August 2008