Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

room stats?

I have a vaillant turbomax vuw gb282,can I fit a room stat and if so how,As I cannot find the data sheet.thankyou.
david lucas, August 2008
turn off power at fused spur or socket, then you drop down the main control panel at the front, (two plastic screws on top left and right corners), remove control board cover, on the front right side of the board you'll see a terminal block, live neutal earth etc. terminals 3 and 4 are the stat live and switched live respectively terminal 5 is neutral for the stat anticipator.

tojo, August 2008
link Click here to see other fixes for Vaillant VUW GB282.