BA asked ... Microsoft account "too many requests" error?    |    jason asked ... Daf cf 85?    |    Roger Kipp asked ... Jvc th-505?    |    Paul Dennis Newman asked ... Gardenline GLS 36K scarifier?    |    Cam Tait asked ... How can I fix my Bison 50 stair lift?    |    Click here to ask your question

POTTERTON SUPREMA 60L?

When the hot water and central heating are turned off by the controller the central heating pump continues to run and the gas boiler 'locks out'. The pump continues to run (for hours) until the boiler is reset. What is the likely cause of this intermittent fault?
Chris Smith, September 2008
pcb is main cause of problems with this boiler.if the boiler work after you reset it then pcb is the problem.these boiler should have pump over run which is proberly why the pump still runs.when off.an decent engineer will fix this.pcb are over priced.anything between £150-250.potterton are the cause of this.as am not on site cant be 100% but hopes this helps.

james turley, September 2008
link Click here to see other fixes for Potterton.