GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Chaffoteaux & Maury boiler no heating or water?

I have got a Chaffoteaux & Maury combi boiler, i have no heating or hot water, i think it is becuase i have no water pressure as the pressure gage is showing close to 0, i havnt got the instuctions as last occupier didnt leave them..i'm freezing how do i add more pressure?help
Stacy, October 2008
Sorry, I hit the wrong button, this should have been a question.

Steve Moody, December 2013
When I open my hot tap the boiler takes a long time to kick in. Sometimes I have to open two taps.
Could it be a sticking pressure valve or a problem with the three way valve?

Steve Moody, December 2013
HI all. I have problem with Chaff MINIMA boiler.
Ariston have engineers but not in my area and will not travel. So need help! When boiler fires up the flue pipes blow apart at joints. I can only think this is due to late combustion of the gas? Any one come across this before and know the fix so I can get an engineer in to do work.

Wayne, June 2013
My boiler is saying a 41

Suzanne, March 2013
my chaffoteaux and maury boiler keeps dropping pressure yet it dont leak water from any pipes,the engineer came out and pumped the tank at the back but it didnt last long b4 it wasnt working again,could u please help?

fred flintstone, March 2012
britony combi se 80 . flashing up 80 40 ?

mick, December 2008
Stacy, I hope you sorted your problem with your boiler however here is the way to increase the pressure in the system.
Look for a braided flexi-pipe with a black lever arm connected between the rising/incoming cold mains water pipe{15mm/1/2in} and the central heating pipe{22mm/3/4in}
this is located just below the boiler in most cases.
Open the valve with the lever arm and observe the pressure dial indicator then close the valve completely when the pressure is 1.5, do not go any higher than this.
If after a short period of time (a few days or so)the pressure drops to zero again then you have another fault which requires attention(poss failed expansion vessel) and you will require the services of a qualified heating engineer.

Freddy2, December 2008
go to http://www.chaffoteaux.co.uk and download the user manual

Chopper Harley, December 2008
I have a similar problem. There is a black turn knob underneath which is the water in-take valve. Open that a little bit and watch the pressure rise to abot 2. Then close the knob(I THINK you are supposed to close it .... 99% sure but not 100% sure).
ANyways, that should restore the pressure.

Sid Syed, October 2008
link Click here to see other fixes for Chaffoteaux.