Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

Glowworm economy plus 40B problem?

My Glowworm economy plus 40B, fires up OK from cold when calling for heat but main burner goes out after a few minutes, have checked thermostat and power to gas valve soilinoid both OK when calling for heat. Do I have a faulty gas valve or soliniod?

Thanks
John, October 2008
The gas valve solenoid coil went high resistance after a few minutes use causing the gas valve to drop out, changing coil fixed the problem

JB, November 2011
Have you checked the header tank is full of water.The boiler will be shutting off as a safety measure if the tank in the loft is empty.If it is empty push the ballvalve down,the coil will refill with water then the boiler will refire up.

Tony S, October 2008