Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Click here to ask your question

Glowworm economy plus 40B problem?

My Glowworm economy plus 40B, fires up OK from cold when calling for heat but main burner goes out after a few minutes, have checked thermostat and power to gas valve soilinoid both OK when calling for heat. Do I have a faulty gas valve or soliniod?

Thanks
John, October 2008
The gas valve solenoid coil went high resistance after a few minutes use causing the gas valve to drop out, changing coil fixed the problem

JB, November 2011
Have you checked the header tank is full of water.The boiler will be shutting off as a safety measure if the tank in the loft is empty.If it is empty push the ballvalve down,the coil will refill with water then the boiler will refire up.

Tony S, October 2008