Ideal Standard Classic FF 60?

Hi, my boiler pilot light does not come on when i switch on the boiler i hear the fan run but nothing else happens, any ideas?
Alan, October 2008
Hi, thanks for the replies Ive just got back from a short break. Is their a way to test the pressure from the fan? Reading my manual I found recently it asks "Is pressure difference at switch greater than 0.9 mbar" but dont know how i would test it, u-gauge maybe?

Alan, October 2008
check the items listed below for correct operation

(a) fan
(b) venturi
(c) venturi tubes
(d) air pressure switch
(e) ignition clectrode or leed
(f) pcb

universal heating ltd, October 2008
as the fan is running check that both the tubes from the exhaust fan to the pressure switch are sound and connected o.k if the pressure switch is making and it still does not fire up then you should suspect the control board PCB.

mr knowitall, October 2008
air pressure switch is in sequence between fan and ignition

iain, October 2008