I have a Potterton Suprima 80L. When going through the initial conditions check (fault finding guide) I get the following problem:
With mains supply OFF, heating timers OFF, boiler user control (temperature control) set to 0 and gas supply ON all boiler lights are OFF which is correct. Turn mains supply ON and red, green boiler lights and pump come on together for 3 secs which is also correct. Red light is NOT flashing, turn heating timers ON - thermostats calling for heat and green light on boiler begins to flash. All OK to this point which is where the problem arises as follows:
The boiler now fires up (green light on constant and red light off) and continues to burn WITHOUT me turning up the boiler temperature control which is still at 0!
Is the boiler temperature control faulty, or is it the overheat thermostat, or is it something else? (new PCB and thermister fitted within the last few days.........)