Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

potterton puma 80, ?

AFTER RUNNINING A BATH the boiler pilot light gose out and you have to relight the boiler
mick, January 2009
What does the DHW Diaphram look like and where in the boiler is it located please ?

Greg, January 2009
It has a DHW diaphram moving a pin which hits a flow switch. My best guess is that the pin isn't returning fast enough leaving the boiler fired up like there is still a demand for hot water but nowhere for the heat being generated to go. Run a tap and see when you switch it off how long it takes for the boiler to go out.
If it takes a while, that is most likely to be the problem and a replacement diaphram and some silicone grease to the pin should sort the problem.

Iain, January 2009