Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

radiator?

all my radiators work except 1 have bled system changed thermostat bled radiator still no heat (help)
ken, January 2009
It may be that all the heat is being used up by the other radiators before the water reaches the cold one.

1) Crank up the water temperature at the boiler a bit if you can
2) Speed up the circulating pump if you can to get the water round the system a bit quicker
3) Consider balancing the radiators - close off the lock valves a bit on the warm ones and open the lock valve a bit on the cold one... see...

http://www.miketheboilerman.com/balancing.htm

Peccavi, January 2009