GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

boiler pressure?

The water pressure on the boiler was low, zero infact, so i have attempted to refill the system. I can hear the water going in but the gauge has not moved now i'm concerned that if the gauge is broken the water pressure is going to be to high.
Tina Clough, January 2009
Is your boiler working? if yes then there is pressure in the system and it will be a faulty guage. If it does not work then it may be that the pressure is too low and you have a leak in your system. If the pressure was too high then your pressure relief valve would blow. (Probably looks like a red cap in your boiler, or a bent copper pipe on your outside wall) If no signs of that then there is a good chance you may have a leak somewhere you cant see it on your radiator pipework, so I would get it looked at.

Delboy, January 2009