Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Click here to ask your question

Ravenheat Silver Star LS 80?

The boiler fails to start with heating or domestic hot water. There is 230v into the control panel through the timer control, however, there is no 230 v at the pump or fan. All auxiliary controls appear to be working (summer/winter switch, low press switch, timer outlet) Possibility that the PCB is defective but nothing obvious, before paying £130 for a replacement would like to know if there is anything else I should check.
Taff, February 2009
check the pump to see if its stuck undo slotted screw in the middle of pump and remove insert screwdriver and turn pump had the same problem thats how mine was solved dont forget turn off power before you do it also you will get a small amount of water leaking out so use abit of rag

rocky, February 2009