Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

How to fault find on Potterton Netaheat Profile 40?

There is no ignition to fire the boiler.
Eric Harkins, February 2009
These are complicated Eric.Firstly make sure the overheat button hasnt popped out.It just needs pressing in and away you will go.If thats ok is the fan definitely running.Make sure if youve had any snow that the flue outside is clear as this will cause many boilers to fail.If the fan is running it could be the pressure switch which if it isnt making wont send power to the pcb for ignition to take place.Difficult mate,as you need to strip it if its not the simplest of faults.

Tony S, February 2009