Dwayne B. asked ... Intermittent (twice) Then Complete Loss of Power?    |    Aunt Bee asked ... Bernina Update 1630 work light not working?    |    Larry asked ... Hybrid Weed wacker not working with battery?    |    Dan asked ... Why is Google Keep so slow on my iPhone?    |    dave s asked ... Transmission not working?    |    Click here to ask your question

DRAYTON DIGISTAT RF1 WIRELESS THERMOSTAT?

Help it looks like my wireless thermostat has crashed leaving me with no heating or water. How do i reset it? i have a white box next to boiler and there is a red light next to 'alarm'
Beverley Andrews, February 2009
Thank you so much Jim. Followed it to the word and it worked a treat. You are a godsend!!!!!!!! Bless you xx

Fran, January 2015
Thanks Jim, for the second time this fantastic advice has kept us warm! Happy New Year!

Chris, January 2011
Hi Jim, found your answer - Now have heating again - Many thanx!

Shauny, November 2010
Jim your'e a star, that worked. restting the receiver. nevr evn crossed my mind.
Thanks, that saved an expensive callout fee

Ken, October 2010
thank you jim, worked atreat your astar

Tony H., October 2010
If this doesn`t work be sure to check the connections to the batteries. Do not assume that just because the RF1`s display comes back on that they are both OK- the LH drawer does the display - on teasing out the connections to the RH batteries the SCR jumped into life; this was at my 20th attempt.

Frustratedby21C, August 2010
Thanks for that Jim, my 83 year old mum had been without heating last weekend after batteries went on thermostat. I've downloaded the instructions for next time!
http://www.draytoncontrols.co.uk/search.aspx?search=Digistat%20RF1%20Wireless%20System&page=1

Gill, March 2010
Thank you Jim

Phil, March 2010
Give the Man a Coconut, followed to the letter works a treat, great stuff Jim, thanks a heap.

Roy, February 2010
Worked for me too. Followed instructions to the letter and it worked first time.
Symptons are:
1. Programmer (is showing 'ON')
2. Digistat RFI (Roomstat) "SET" temp is higher than RFI shows as room temp)
i.e. are demanding heat
3. Boiler is "ON", not showing any error code and is not firing up.

Thanks!!

Tim "the Smallholder", January 2010
done what instructions said worked for us aswell
so well done whoever left instructions about
changing the batteries

mrs t., January 2010
Just used this - worked first time, thanks so much

ColdinLeedsUK, January 2010
Thanks Jim, you're a star,saved us a few bob over this winter.Rob and Rowena.........Happy New Year mate!

Rob, January 2010
thanks jim, worked fine for me as well, saving me the cost of an engineer! cheers

matt e, November 2009
The above just worked for me perfectly. THANKS

Phil Reynolds, February 2009
1st open the draws on the wireless room stat and replace the 4 AA battery's but do not close the draws,then take it to within 1meter of the receiver,turn the mains off then on again, press button 1 hold it and press button 2 until the red light flashes(learn mode)now first close the right hand draw then the left hand draw of the wireless stat and the display should come on press plus/minus and it should start working,if not both the receiver and stat will need replacing,good luck