Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

no heat to down stairs radiators?

i have put a new radiator in downstairs and now am having trouble getting any heat to all the downstairs radiators. upstairs is boiling.i turned upstairs off and bled downstairs ( over two days worth of bleeding )and they came warn until i turned upstairs back on then they went cold again. help!!!!!!
jif, February 2009
Find the circulating pump and increase the speed.

Turn up the thermostat control on the boiler by a notch.

Balance the radiators i.e. close off the outlets (lock shield valves) a bit on the upstairs rads and open them up a bit on the downstairs ones...see...

http://www.miketheboilerman.com/balancing.htm

so that the available heat is being shared more equally between upstairs and downstairs.

Peccavi, February 2009