3 hours ago Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Click here to ask your question

Alpha boiler cb28?

When running the hot water it goes cold after a couple of minutes for a few seconds and then returns to normal, this happens every 4-5 minutes.
Geoff Brookes, March 2009
Hi Geoff,

It could be that the diverter is not closing off the ch circuit and the water is not circulating around the secondary heat exchanger correctly, therefore causing the boiler to heat up rapidly and then cut off again. Another thing is to check that the water pressure is correct 1-1.5 bar, it may also be that the boiler is scalled up.

gary, March 2009