Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Alpha boiler cb28?

When running the hot water it goes cold after a couple of minutes for a few seconds and then returns to normal, this happens every 4-5 minutes.
Geoff Brookes, March 2009
Hi Geoff,

It could be that the diverter is not closing off the ch circuit and the water is not circulating around the secondary heat exchanger correctly, therefore causing the boiler to heat up rapidly and then cut off again. Another thing is to check that the water pressure is correct 1-1.5 bar, it may also be that the boiler is scalled up.

gary, March 2009