GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can i fix a fault EA, on worcester bosch HEplus40?

How can i fix a fault EA, on worcester bosch HEplus40
the igniter comes on for a bit, struggles and then fails with error code EA

if i leave the boiler off for a while, then switch on it works for a bit longer, but then fails again.

Thanks
G, March 2009
EA is ignition lockout, this means that something in the boiler's startup sequence has gone tits up. It could be down to something silly like gas pressure being too low (not something you can check yourself), it could be a problem with combustion (not enough air - there is a flap valve in the fan that can cause this), spark not being strong enough to get things lit (or even mistimed). Can even be a flue fault if the boiler cannot get rid of its exhaust fast enough.

The only things you CAN check as a householder is that the flue terminal is not obstructed, that you definitely have the gas on (check your gas fire or hob works OK) and also that the condensate drain for the boiler is not blocked up as this too can throw up EA faults.

Bunslinger, March 2009