tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Charles asked ... Replace Belle switch?    |    Tracy asked ... Drum housing Defy DAW 317?    |    Click here to ask your question

simpson delta 422 model 36e422p+ o3?

motor intermittently cuts out on wash cycle. all other cycles are ok. how to check electronic forward reversing module. Need wiring diagram
Colin, March 2009
Simpson Type Electronic Forward Reversing Module
by Paul Pittard

Test Procedure for modules with wire leads
To Test Agitation
1. Remove Wires EA, CA and CB.
2. Disconnect Cord Active from timer
3. Connect Cord Active to EA on the EFR Module
4. Connect CA to Neutral (this gives normal agitation)
5. Make all wires safe and turn on the power. (Normal agitation should be observed)
6. Turn Off Power
7. Remove CA from Neutral
8. Connect CB to Neutral (this gives gentle Agitation)
9. Make all wires safe and power on (gentle agitation should be observed)
To Test Spin Motor action
1. Leave EA connected to Cord active and CB connected to neutral
2. Connect CA to neutral as well
3. Make all wires safe and turn on power (single direction agitator rotation should be observed.) Note: Spin does not occur as clutch solenoid (or brake motor) is not energised
4. Reconnect wires to original positions

Later Modules with male terminals
The agitation function is similar to described above, these modules do not have a CB terminal, and active for spin is supplied direct from a timer switch. On the late modules, if CA is connected to Neutral it gives normal agitation. If CA is open circuit, it gives gentle agitation.

From VAIA Newsletter Oct 2007, April 2012
link Click here to see other fixes for Simpson.