Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

scantronic 9450?

i moved my scantronic 9450 to another wall, i now have a red light labled tampered lit. how do i fix this.
neil, April 2009
OMG John. Poor Neil is now wishing he had never asked for help. Mutimeter set to continuity, you mean ohms. You cant instruct people to start opening lids of control panels where there is live mains, suppose Neil has a heart condition and accidently slips and touches 240ac. If Neil could do the above he wouldnt be on here asking for help would he.
Think John, and keep it simple for the public

J, April 2009
It depends on where the tamper fault is. I'm assuming you have also had to relocate all the wiring to the panel so the two main possible causes are a loose panel lid or a wiring fault in the detectors tamper circuit or a bell box tamper fault.
CHECK THE PANEL LID FIRST!!
You will have to connect a multi meter ( set to measure continuity) between the A/T terminals on the right hand side of the panel circuit board & you need to have confirmation of a closed circuit.
To check the bell box tamper you have to connect a multi meter (set to 12 volt dc) with the red lead to terminal +12v & the black lead to terminal TR on the bottom of the circuit board. You need to have a reading of at least 12 volts or more (usually 13volts).

John, Alarms Direct, April 2009