Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

Pilot light problem?

Have a Glow-Worm Space-Saver 45-60 B, Boiler.
The pilot light has a intermittent tendency to go out. Is this a cleaning problem or is a spare part required ?
Dave, April 2009
Thanks Mr K
Boiler descaled, radiators flushed out and thermocouple replaced.
Worked fine for a few days with both water and central heating on.

Now water heating function perfect when used without Central heating.
With water and central heating on, radiators reach required temperature and main burner closes down the pilot light is extinguishes as well.

Dave, June 2009
Thanks Mr K, Think it must be the Thermocouple needing replaced.
As you say this model is very old so where will I get a replacement part, Our would a universal thermocouple fit?

Dave, April 2009
Boiler is old and seems to have scaled up in heatexchanger. pilot will light and will go out after a while when boiler get hot due to overheat sence temp. and interupt the link to thermocouple to shut off. answer is to descal boiler only. or replace thermocouple and see if problem solved.

Mr K, April 2009