andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

worcester bosch 24i intermittent ignition?

Hi,

My WB24i has an intermittent ignition fault developed over the last few weeks.

the DHW demand seems ignite the boiler with no problem.

the CH demand however will USUALLY ignite the boiler on its first attempt, however as the CH begins to "cycle" on and off with water temp, it struggles to relight the boiler at each cycle.

the "ticking" of the spark can be heard but many times not seen. the boiler locks out after several seconds of "ticking" without ignition, forcing a reset by the off switch or ceasing CH demand.

the spark electrodes were changed for new ones this morning and set to distances specified in the manual. with no difference in effect.

gas jet pressure was also checked and tweaked this morning too. also entire ignition chamber was swept out and cleaned.

anyone any ideas? thanks in advance

Steve
Steve Day, April 2009
I think this may relate to the PCB. Try to apply pressure on the temperature control knob. if the clicking occurs whlst pushing the knob, you're in a need of a new PCB.

Sam, April 2009
have the ignition leads been changed aswell as the probes if yes, check the ignition board is actually send voltage at point of ignition, could be the board playing up

STE, April 2009
link Click here to see other fixes for Worcester Bosch 24i.