narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

how do i repair my shower meynell viscount 017577?

my shower is difficult to turn on and off and when it is on although the hot water pipe is hot the shower is cold. it seems to be letting to much cold water through. can i repair it?
mikey, April 2009
Turn shower control to maximum setting. Remove cap/cover on head assembly. Insert 2.5mm hexagon allen key into centre of valve head. Turn key anticlockwise to increase temperature, or clockwise to decrease temperature. Remove key and turn on mixer to check temperature.